AI Summary
Water Quality Sensors for professionals

The Industrial Grade Analog PH Sensor Kit is a mid-range water quality sensors designed for professionals. It features Model No. / Name: pH Sensor and Operating Voltage (VDC): 5. Customers praise its fast and responsive and accurate and reliable.

fast and responsiveaccurate and reliable
₹2,475
Free Shipping💵 COD Available

Available Offers

Free Delivery on this order. No minimum order value.

15-Day Easy Returns — hassle-free return & full refund.

Secure Payment — 100% safe checkout with UPI, Cards & Net Banking.

Total: ₹2,475
Buying tip: A well-rounded choice at a fair price. Recommended for most buyers.
Estimated delivery: 16 Aug30 Aug
Free Shipping
Pan India delivery
15-Day Returns
Hassle-free policy
Secure Payment
Razorpay protected
Quality Assured
Vetted products only

Available Offers

💳

5% Cashback

Pay with UPI & get 5% cashback (up to ₹50) via Razorpay

🏦

No-Cost EMI

Available on select bank cards at checkout. 0% interest for 3 months.

📦

Free Shipping

Free delivery on all orders. No minimum order value.

💵

Cash on Delivery

COD available on orders up to ₹5,000 across India.

Quick Specs

Model No. / Name: pH Sensor
Operating Voltage (VDC): 5
Module Size (LxWxH) mm: 50 x 47 x 16
Measuring Current Range: 0 - 14 PH
Accuracy: ±0.01 pH
Response Time (uS): ≤ 1min

Ideal For

Electronics projectsArduino / Raspberry Pi buildsPrototyping
Share:
SKU: robu-235871Category: Water Quality Sensors

About This Product

The Industrial Grade Analog PH Sensor Kit is a mid-range water quality sensors designed for professionals. Customers highlight its fast and responsive and accurate and reliable.

Key Specifications

  • Model No. / Name: pH Sensor
  • Operating Voltage (VDC): 5 — works with standard household power
  • Module Size (LxWxH) mm: 50 x 47 x 16
  • Measuring Current Range: 0 - 14 PH — reliable connection even at a distance
  • Accuracy: ±0.01 pH
  • Response Time (uS): ≤ 1min
  • Cable Length: 75
  • Sensor size: 150, Φ12 pH

Why Buy from Pricio?

Pricio sources this product directly, cutting out multiple middlemen. Every order includes free shipping, a 15-day return policy, and secure payment via Razorpay.

This is Industrial Grade Analog PH Sensor Kit. Need to measure water quality and other parameters but haven’t got any low-cost pH meter? Find it difficult to use with Arduino? Here, we have an Industrial Grade Analog PH Sensor Kit. This probe can be used with this pH sensor module.

The Analog pH Sensor Kit is specially designed for Arduino controllers and has a built-in simple, convenient, and practical connection and features. It has an LED that works as the Power Indicator, a BNC connector, and a PH2.0 sensor interface. To use it, just connect the pH sensor with the BND connector, and plug the PH2.0 interface into the analog input port of any Arduino controller. If pre-programmed, you will get the pH value easily. Comes in a compact plastic box with foams for better mobile storage

 

Note: PH SENSOR color may vary (black or green), but functionality remains the same .

Circuit Diagram: Applications  

  • Water quality testing
  • Aquaculture

Note: This is a laboratory probe, it can't be immersed in the liquid for a too long time.

To Explore More pH Sensors, Click here


Source Code:

#define SensorPin A0          // the pH meter Analog output is connected with the Arduino’s Analog

unsigned long int avgValue;  //Store the average value of the sensor feedback

float b;

int buf[10],temp;

void setup()

{

  pinMode(13,OUTPUT);  

  Serial.begin(9600);  

  Serial.println("Ready");    //Test the serial monitor

}

void loop()

{

  for(int i=0;i<10;i++)       //Get 10 sample value from the sensor for smooth the value

  {

    buf[i]=analogRead(SensorPin);

    delay(10);

  }

  for(int i=0;i<9;i++)        //sort the analog from small to large

  {

    for(int j=i+1;j<10;j++)

    {

      if(buf[i]>buf[j])

      {

        temp=buf[i];

        buf[i]=buf[j];

        buf[j]=temp;

      }

    }

  }

  avgValue=0;

  for(int i=2;i<8;i++)                      //take the average value of 6 center sample

    avgValue+=buf[i];

  float phValue=(float)avgValue*5.0/1024/6; //convert the analog into millivolt

  phValue=3.5*phValue;                      //convert the millivolt into pH value

  Serial.print("    pH:");  

  Serial.print(phValue,2);

  Serial.println(" ");

  digitalWrite(13, HIGH);       

  delay(800);

  digitalWrite(13, LOW);

Step to Use the pH Meter:

Cautions:

  1. Please use an external switching power supply, and the voltage as close as possible to the +5.00V. More accurate the voltage, the higher the accuracy!
  2. Before the electrode is continuously used every time, you need to calibrate it by the standard solution, in order to obtain more accurate results. The best environment temperature is about 25 ℃, and the pH value is known and reliable, close to the measured value. If you measure the acidic sample, the pH value of the standard solution should be 4.00. If you measure the alkaline sample, the pH value of the standard solution should be 9.18.Subsection calibration, just in order to get better accuracy.
  3. Before the pH electrode is measured in different solutions, we need to use water to wash it. We recommend using deionized water.
  4. Connect equipment according to the graphic, that is, the pH electrode is connected to the BNC connector on the pH meter board,and then use the connection lines, the pH meter board is connected to the analog port 0 of the Arduino controller. When the Arduino controller gets power, you will see the blue LED on board is on.
  5. Upload the sample code to the Arduino controller.
  6. Put the pH electrode into the standard solution whose pH value is 7.00,or directly shorten the input of the BNC connector. Open the serial monitor of the Arduino IDE, you can see the pH value printed on it, and the error does not exceed 0.3. Record the pH value printed, then compared with 7.00, and the difference should be changed into the "Offset" in the sample code. For example, the pH value printed is 6.88, so the difference is 0.12. You should change the "# define Offset 0.00" into "# define Offset 0.12" in your program.
  7. Put the pH electrode into the pH standard solution whose value is 4.00. Then wait about one minute, adjust the gain potential device, let the value stabilize at around 4.00. At this time, the acidic calibration has been completed and you can measure the pH value of an acidic solution.

Note: If you want to measure the pH value of other solutions, you must wash the pH electrode first!


Package Includes:

1 x pH probe with cable and BNC connector.

1 x pH sensor circuit board.

Setup Guide

1
Identify the pins
Locate VCC (power), GND (ground), and data pins (SDA/SCL for I2C, MOSI/MISO for SPI, or TX/RX for UART). Refer to the pinout diagram on the product page.
2
Wire to your microcontroller
Connect VCC to 3.3V or 5V (check the module spec), GND to GND, and data pins to the appropriate GPIO pins on your Arduino or Raspberry Pi.
3
Install libraries
In Arduino IDE, go to Sketch → Include Library → Manage Libraries and search for the sensor library. Install the recommended version.
4
Upload example sketch
Open File → Examples → [library name] → Basic Example. Upload to your board and open Serial Monitor to view output.
5
Calibrate if needed
Some sensors (temperature, humidity, distance) may need a short warm-up period or calibration. Run the calibration sketch if provided.