Skip to main content
Free Delivery  ·  COD Available  ·  15-Day Returns
Pricio
Renke RS-PH-N01-2-201T Industrial water PH sensor, 0℃ ~80℃; Resolution: 0.1℃,0~14.00pH; division value: 0.01, (Type RS485) — image 1
Hover to zoom

1 / 2 · Click to enlarge

Renke

Renke RS-PH-N01-2-201T Industrial water PH sensor, 0℃ ~80℃; Resolution: 0.1℃,0~14.00pH; division value: 0.01, (Type RS485)

30+ bought in past month
AI Summary
Water Quality Sensors for professionals

The Renke RS-PH-N01-2-201T Industrial water PH sensor, 0℃ ~80℃; Resolution: 0.1℃,0~14.00pH; division value: 0.01, (Type RS485) by Renke is a premium water quality sensors designed for professionals. It features Item Type: Sensor and Voltage Rating: 10 to 30.

₹18,300
Free Shipping💵 COD Available

Available Offers

Free Delivery on this order. No minimum order value.

15-Day Easy Returns — hassle-free return & full refund.

Secure Payment — 100% safe checkout with UPI, Cards & Net Banking.

Total: ₹18,300
Buying tip: A top-tier option — the best features and quality available in this category.
Estimated delivery: 17 Aug31 Aug
Free Shipping
Pan India delivery
15-Day Returns
Hassle-free policy
Secure Payment
Razorpay protected
Quality Assured
Vetted products only

Available Offers

💳

5% Cashback

Pay with UPI & get 5% cashback (up to ₹50) via Razorpay

🏦

No-Cost EMI

Available on select bank cards at checkout. 0% interest for 3 months.

📦

Free Shipping

Free delivery on all orders. No minimum order value.

💵

Cash on Delivery

COD available on orders up to ₹5,000 across India.

Quick Specs

Item Type: Sensor
Voltage Rating: 10 to 30
Power Consumption (W): 0.6
Signal Output: RS485/4~20mA/0~5V/0~10V
Resolution: 0.01pH
Operating Temperature (°C): 0~80

Ideal For

Electronics projectsArduino / Raspberry Pi buildsPrototyping
Share:
SKU: robu-2115442Category: Water Quality Sensors

About This Product

The Renke RS-PH-N01-2-201T Industrial water PH sensor, 0℃ ~80℃; Resolution: 0.1℃,0~14.00pH; division value: 0.01, (Type RS485) by Renke is a premium water quality sensors designed for professionals. It delivers reliable performance at an accessible price.

Key Specifications

  • Item Type: Sensor
  • Voltage Rating: 10 to 30 — works with standard household power
  • Power Consumption (W): 0.6
  • Signal Output: RS485/4~20mA/0~5V/0~10V
  • Resolution: 0.01pH
  • Operating Temperature (°C): 0~80
  • Environmental Temperature (°C): 0-60℃, relative humidity <85%
  • Shipping Weight: 0.59 kg

Why Buy from Pricio?

Pricio sources this product directly, cutting out multiple middlemen. Every order includes free shipping, a 15-day return policy, and secure payment via Razorpay.

Note: Customize this product to meet your unique requirements—reach out to sales@Pricio.in for more information.  
For Customization:
  RS-PH-*-2-* industrial pH sensor adopts conventional composite electrode, which is suitable for the measurement of conventional sewage, tap water, environmental sewage, domestic sewage and other solutions. The pH measure range is between 0~14pH, and the resolution is 0.01pH. The adaptation temperature of the electrode is 0-80℃. This water pH sensor consists of two parts: a data collector and an electrode probe. The ph electrode probe has four lengths of 5m, 10m, 15m, and 20m. The housing of the data collector is IP65 protection grade, which can be used in outdoor rain and snow environment. When it detects that the PH concentration exceeds the preset alarm value, it can provide multiple alarm methods such as interface alarm, sound and light alarm, SMS alarm, telephone alarm, email alarm, etc., to remind managers to troubleshoot the cause of excessive PH value in time, and record the event for information Call and analyze. Note: The actual product may vary in slightly variation with the image shown. Refer to the datasheet in the ATTACHMENTS section for more info. regd. the product.

Features:

  1. High performance: high accuracy, fast response, good repeatability
  2. Universal protocol: MODBUS RS-485 or 4~20mA current
  3. Wide-range power supply: 10V ~ 30VDC
  4. Robustness: suitable to be immersed in water for a long time
  5. Maintainance-Free: advanced junction design, no clogging
  6. Durable: anti-corrosion, automatic temperature compensation
  7. User-friendly: Easy to install and integrate

Applications:

  1. Industrial sewage
  2. Domestic sewage
  3. Agriculture
  4. Aquaculture
  5. Other scenarios in a non-corrosive weak acid and weak alkali environment

Package Includes:

1 x Renke RS-PH-N01-2-201T Industrial water PH sensor, 0℃ ~80℃; Resolution: 0.1℃,0~14.00pH; division value: 0.01, (Type RS485)

Setup Guide

1
Identify the pins
Locate VCC (power), GND (ground), and data pins (SDA/SCL for I2C, MOSI/MISO for SPI, or TX/RX for UART). Refer to the pinout diagram on the product page.
2
Wire to your microcontroller
Connect VCC to 3.3V or 5V (check the module spec), GND to GND, and data pins to the appropriate GPIO pins on your Arduino or Raspberry Pi.
3
Install libraries
In Arduino IDE, go to Sketch → Include Library → Manage Libraries and search for the sensor library. Install the recommended version.
4
Upload example sketch
Open File → Examples → [library name] → Basic Example. Upload to your board and open Serial Monitor to view output.
5
Calibrate if needed
Some sensors (temperature, humidity, distance) may need a short warm-up period or calibration. Run the calibration sketch if provided.